Argus-Power-System-MIB
Monitored by Observium This MIB defines the information block(s) available in CXC RMU
as defined by the following list:
- upsDevice: the CXC-series of controllers
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Device identity
Sensors
Status
Explore Observium network monitoring
- Source file
Argus-Power-System-MIB- Last revised
- Identity
argus- Base OID
1.3.6.1.4.1.7309
Imported Objects
| SNMPv2-SMI | enterprises MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) |
Net-SNMP examples using the alpha MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'Argus-Power-System-MIB' -M '/opt/observium/mibs/alpha:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'Argus-Power-System-MIB::argus'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Argus-Power-System-MIB' -M '/opt/observium/mibs/alpha:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Argus-Power-System-MIB::argus'
Objects (76)
18 directly used by Observium
Showing 76 of 76 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
| argus | .1.3.6.1.4.1.7309 | |
.1.3.6.1.4.1.7309.6 | ||
.1.3.6.1.4.1.7309.6.1 | ||
.1.3.6.1.4.1.7309.6.1.1 | ||
| upsIdentManufacturer | OctetString | .1.3.6.1.4.1.7309.6.1.1.1 |
| OctetString | .1.3.6.1.4.1.7309.6.1.1.10 | |
| OctetString | .1.3.6.1.4.1.7309.6.1.1.11 | |
| OctetString | .1.3.6.1.4.1.7309.6.1.1.12 | |
| OctetString | .1.3.6.1.4.1.7309.6.1.1.13 | |
upsIdentDater/w | OctetString | .1.3.6.1.4.1.7309.6.1.1.14 |
upsIdentTimer/w | OctetString | .1.3.6.1.4.1.7309.6.1.1.15 |
| upsIdentProductCodeOBS ✓ | OctetString | .1.3.6.1.4.1.7309.6.1.1.2 |
| upsIdentModelOBS ✓ | OctetString | .1.3.6.1.4.1.7309.6.1.1.3 |
| upsIdentUPSSoftwareVersionOBS ✓ | OctetString | .1.3.6.1.4.1.7309.6.1.1.4 |
| upsIdentAgentSoftwareVersion | OctetString | .1.3.6.1.4.1.7309.6.1.1.5 |
| upsIdentName | OctetString | .1.3.6.1.4.1.7309.6.1.1.6 |
| upsIdentAttachedDevices | OctetString | .1.3.6.1.4.1.7309.6.1.1.7 |
| OctetString | .1.3.6.1.4.1.7309.6.1.1.8 | |
| OctetString | .1.3.6.1.4.1.7309.6.1.1.9 | |
.1.3.6.1.4.1.7309.6.1.2 | ||
| upsBatteryStatus | Enumeration | .1.3.6.1.4.1.7309.6.1.2.1 |
| upsMinutesOnBattery | minutesInteger32 | .1.3.6.1.4.1.7309.6.1.2.2 |
| upsBatteryVoltageOBS ✓ | 0.1 Volt DCInteger32 | .1.3.6.1.4.1.7309.6.1.2.3 |
| upsBatteryChargingCurrentOBS ✓ | 0.1 Amp DCInteger32 | .1.3.6.1.4.1.7309.6.1.2.4 |
| upsBatteryCapacityOBS ✓ | 0.1 Amp DCInteger32 | .1.3.6.1.4.1.7309.6.1.2.5 |
| upsBatteryTemperatureOBS ✓ | degrees CentigradeInteger32 | .1.3.6.1.4.1.7309.6.1.2.6 |
| percentageInteger32 | .1.3.6.1.4.1.7309.6.1.2.7 | |
.1.3.6.1.4.1.7309.6.1.3 | ||
| upsInputNumLines | Integer32 | .1.3.6.1.4.1.7309.6.1.3.1 |
| upsInputTable | .1.3.6.1.4.1.7309.6.1.3.2 | |
| upsInputEntry | .1.3.6.1.4.1.7309.6.1.3.2.1 | |
| upsInputLineIndex | Integer32 | .1.3.6.1.4.1.7309.6.1.3.2.1.1 |
| upsInputFrequencyOBS ✓ | HertzInteger32 | .1.3.6.1.4.1.7309.6.1.3.2.1.2 |
| upsInputVoltageOBS ✓ | 0.1 RMS VoltsInteger32 | .1.3.6.1.4.1.7309.6.1.3.2.1.3 |
.1.3.6.1.4.1.7309.6.1.4 | ||
| upsOutputSource | Enumeration | .1.3.6.1.4.1.7309.6.1.4.1 |
| upsOutputFrequencyOBS ✓ | 0.1 HertzInteger32 | .1.3.6.1.4.1.7309.6.1.4.2 |
| upsOutputNumLines | Integer32 | .1.3.6.1.4.1.7309.6.1.4.3 |
| upsOutputTable | .1.3.6.1.4.1.7309.6.1.4.4 | |
| upsOutputEntry | .1.3.6.1.4.1.7309.6.1.4.4.1 | |
| upsOutputLineIndex | Integer32 | .1.3.6.1.4.1.7309.6.1.4.4.1.1 |
| upsOutputVoltageOBS ✓ | 0.1 RMS VoltsInteger32 | .1.3.6.1.4.1.7309.6.1.4.4.1.2 |
| upsOutputCurrentOBS ✓ | 0.1 RMS AmpInteger32 | .1.3.6.1.4.1.7309.6.1.4.4.1.3 |
| upsOutputPowerVAOBS ✓ | VAInteger32 | .1.3.6.1.4.1.7309.6.1.4.4.1.4 |
| upsOutputPowerWattOBS ✓ | WattsInteger32 | .1.3.6.1.4.1.7309.6.1.4.4.1.5 |
| upsPowerFactorOBS ✓ | percentInteger32 | .1.3.6.1.4.1.7309.6.1.4.4.1.6 |
| upsOutputPercentLoadOBS ✓ | percentInteger32 | .1.3.6.1.4.1.7309.6.1.4.4.1.7 |
.1.3.6.1.4.1.7309.6.1.5 | ||
| upsAlarmsPresent | Integer32 | .1.3.6.1.4.1.7309.6.1.5.1 |
| upsAlarmTable | .1.3.6.1.4.1.7309.6.1.5.2 | |
| upsAlarmEntry | .1.3.6.1.4.1.7309.6.1.5.2.1 | |
| upsAlarmId | Integer32 | .1.3.6.1.4.1.7309.6.1.5.2.1.1 |
| upsAlarmDescrOBS ✓ | OctetString | .1.3.6.1.4.1.7309.6.1.5.2.1.2 |
| upsAlarmStatusOBS ✓ | Integer32 | .1.3.6.1.4.1.7309.6.1.5.2.1.3 |
.1.3.6.1.4.1.7309.6.1.6 | ||
| upsConfigLineQualifyTime | secondsInteger32 | .1.3.6.1.4.1.7309.6.1.6.1 |
| OctetString | .1.3.6.1.4.1.7309.6.1.6.10 | |
| OctetString | .1.3.6.1.4.1.7309.6.1.6.11 | |
| upsConfigLineOutputVoltageHighLimit | volttenthInteger32 | .1.3.6.1.4.1.7309.6.1.6.2 |
| upsConfigLineOutputVoltageLowLimit | volttenthInteger32 | .1.3.6.1.4.1.7309.6.1.6.3 |
| upsConfigFanOnTemperature | degreeCInteger32 | .1.3.6.1.4.1.7309.6.1.6.4 |
| Integer32 | .1.3.6.1.4.1.7309.6.1.6.5 | |
| secondsInteger32 | .1.3.6.1.4.1.7309.6.1.6.6 | |
| OctetString | .1.3.6.1.4.1.7309.6.1.6.7 | |
| OctetString | .1.3.6.1.4.1.7309.6.1.6.8 | |
| OctetString | .1.3.6.1.4.1.7309.6.1.6.9 | |
.1.3.6.1.4.1.7309.6.1.7 | ||
.1.3.6.1.4.1.7309.6.1.7.0 | ||
.1.3.6.1.4.1.7309.6.1.8 | ||
| upsExtraCount | Integer32 | .1.3.6.1.4.1.7309.6.1.8.1 |
| upsExtraTable | .1.3.6.1.4.1.7309.6.1.8.2 | |
| upsExtraEntry | .1.3.6.1.4.1.7309.6.1.8.2.1 | |
| upsExtraIndex | Integer32 | .1.3.6.1.4.1.7309.6.1.8.2.1.1 |
| upsExtraName | OctetString | .1.3.6.1.4.1.7309.6.1.8.2.1.2 |
| upsExtraIntegerValue | Integer32 | .1.3.6.1.4.1.7309.6.1.8.2.1.3 |
| upsExtraStringValue | OctetString | .1.3.6.1.4.1.7309.6.1.8.2.1.4 |
Dependencies (1) 1 direct Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- Argus-Power-System-MIBalphaselected
Type Definitions (4)
| OctetString | ||
| Integer32 |
range: 0..2147483647 |
|
| OctetString | ||
| Integer32 |
range: 1..2147483647 |
Notifications / Traps (5)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.7309.6.1.7.0.1 |
A trap issued from a change in state in one of the Alarms on the Novus controller
|
|
.1.3.6.1.4.1.7309.6.1.7.0.2 |
A trap to indicate that the agent software has started up.
|
|
.1.3.6.1.4.1.7309.6.1.7.0.3 |
A trap to indicate that the agent software has shutdown.
|
|
.1.3.6.1.4.1.7309.6.1.7.0.4 |
A trap issued from a change in state in one of the Faults on the Novus controller
|
|
.1.3.6.1.4.1.7309.6.1.7.0.5 |
A trap issued from a change in state in one of the Events on the Novus controller
|