ATEN-PE-CFG Table View
Table-centric layout grouping table, row, and column objects.
Tables
22
Rows
22
Columns
160
usrListTable
table.1.3.6.1.4.1.21317.1.3.2.2.1.1
·
1 row entry
·
47 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk usrListTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::usrListTable'
A list of user. The number of user is given by the value of usrcfgNumber.
Status and parameter values for a pe8208 user.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
The value of usrIndex for the user. We have 1 administrator and 8 users.
The index 9 will be the administrator. |
Integer32 Constraints: range: 1-9 |
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.1 |
||||||||
|
The user's type.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.2 |
||||||||
|
A textual string containing name of the user.
string length: 1~16 |
OctetStringr/w Constraints: range: 1-16 |
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.3 |
||||||||
|
A textual string containing password of the user.
string length: 1~16 |
OctetStringr/w Constraints: range: 1-16 |
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.4 |
||||||||
|
Display or set this user's outlet 1 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.5 |
||||||||
|
Display or set this user's outlet 2 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.6 |
||||||||
|
Display or set this user's outlet 3 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.7 |
||||||||
|
Display or set this user's outlet 4 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.8 |
||||||||
|
Display or set this user's outlet 5 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.9 |
||||||||
|
Dispaly or set this user's outlet 6 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.10 |
||||||||
|
Display or set this user's outlet 7 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.11 |
||||||||
|
Display or set this user's outlet 8 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.12 |
||||||||
|
Display or set this user's outlet 9 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.13 |
||||||||
|
Display or set this user's outlet 10 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.14 |
||||||||
|
Display or set this user's outlet 11 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.15 |
||||||||
|
Display or set this user's outlet 12 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.16 |
||||||||
|
Display or set this user's outlet 13 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.17 |
||||||||
|
Display or set this user's outlet 14 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.18 |
||||||||
|
Display or set this user's outlet 15 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.19 |
||||||||
|
Display or set this user's outlet 16 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.20 |
||||||||
|
Display or set this user's outlet 17 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.21 |
||||||||
|
Display or set this user's outlet 18 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.22 |
||||||||
|
Display or set this user's outlet 19 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.23 |
||||||||
|
Display or set this user's outlet 20 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.24 |
||||||||
|
Display or set this user's outlet 21 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.25 |
||||||||
|
Display or set this user's outlet 22 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.26 |
||||||||
|
Display or set this user's outlet 23 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.27 |
||||||||
|
Display or set this user's outlet 24 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.28 |
||||||||
|
Display or set this user's outlet 25 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.29 |
||||||||
|
Display or set this user's outlet 26 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.30 |
||||||||
|
Display or set this user's outlet 27 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.31 |
||||||||
|
Display or set this user's outlet 28 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.32 |
||||||||
|
Display or set this user's outlet 29 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.33 |
||||||||
|
Display or set this user's outlet 30 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.34 |
||||||||
|
Display or set this user's outlet 31 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.35 |
||||||||
|
Display or set this user's outlet 32 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.36 |
||||||||
|
Display or set this user's outlet 33 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.37 |
||||||||
|
Display or set this user's outlet 34 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.38 |
||||||||
|
Display or set this user's outlet 35 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.39 |
||||||||
|
Display or set this user's outlet 36 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.40 |
||||||||
|
Display or set this user's outlet 37 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.41 |
||||||||
|
Display or set this user's outlet 38 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.42 |
||||||||
|
Display or set this user's outlet 39 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.43 |
||||||||
|
Display or set this user's outlet 40 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.44 |
||||||||
|
Display or set this user's outlet 41 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.45 |
||||||||
|
Display or set this user's outlet 42 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.46 |
||||||||
|
Display or set this user is enable or not
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.47 |
deviceValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.3
·
1 row entry
·
9 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk deviceValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::deviceValueTable'
Device value table. This table displays device's current, voltage, power and power dissipation.
Single deviceValue entry containing device info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of deviceValue.
|
Integer32 Constraints: range: 1-1 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.1 |
|
Device electric current value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.2 |
|
Device voltage value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.3 |
|
Device power value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.4 |
|
Device power dissipation value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.5 |
|
Device input Voltage value. unit:(V)
If the device does not support this OID, we show value 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.6 |
|
Device input Current value. unit:(A)
If the device does not support this OID, we show value 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.7 |
|
Device power Capacity value.unit:(VA)
If the device does not support this OID, we show value 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.8 |
|
Device power Factor value.
If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.9 |
sensorValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.4
·
1 row entry
·
5 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk sensorValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::sensorValueTable'
Device's sensor value table. This table displays sensor's temperature, humidity and pressure.
Single device's sensor value entry containing device info.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Index of sensor number.
|
Integer32 Constraints: range: 1-6 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.1 |
||||||
|
Sensor's Temperature value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.2 |
||||||
|
Sensor's Humidity value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.3 |
||||||
|
Sensor's Pressure value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.4 |
||||||
|
Sensor's Property.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.5 |
deviceOutletStatusTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.5
·
1 row entry
·
2 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk deviceOutletStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::deviceOutletStatusTable'
Device outlet status value table.
Single deviceOutletStatus entry containing device info.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Index of deviceOutletStatus
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1.1 |
||||||||||||||
|
Display outlet status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1.2 |
deviceConfigTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.6
·
1 row entry
·
8 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk deviceConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::deviceConfigTable'
Device configuration table
Single deviceConfig entry containing device info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of deviceConfig
|
Integer32 Constraints: range: 1-1 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.1 |
|
Display or set device minimum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320. NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.2 |
|
Display or set device maximum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device doe… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.3 |
|
Display or set device minimum voltage measurement threshold.
Exapmple: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 900-2600range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.4 |
|
Display or set device maximum voltage measurement threshold.
Example: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not … |
Integer32r/w Constraints: range: 900-2600range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.5 |
|
Display or set device minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not s… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.6 |
|
Display or set device maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not s… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.7 |
|
Display or set device maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the dev… |
Integer32r/w Constraints: range: 0-999990range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.8 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7
·
1 row entry
·
7 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk deviceSensorTresholdTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::deviceSensorTresholdTable'
Device environment value table
Device's sensor Environment entry containing sensor info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of sensor number
|
Integer32 Constraints: range: 1-6 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.1 |
|
Display or set sensor minimum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device doe… |
Integer32r/w Constraints: range: -200-600range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.2 |
|
Display or set sensor maximum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device doe… |
Integer32r/w Constraints: range: -200-600range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.3 |
|
Display or set sensor minimum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 100-950range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.4 |
|
Display or set sensor maximum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: -3000--3000range: 100-950 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.5 |
|
Display or set sensor minimum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device … |
Integer32r/w Constraints: range: -2500-2500range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.6 |
|
Display or set sensor maximum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device … |
Integer32r/w Constraints: range: -2500-2500range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.7 |
dryContactTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.15
·
1 row entry
·
3 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk dryContactTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::dryContactTable'
Device's Dry Contact table.
Single device's dry contact value entry containing device info.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Index of dry contact number.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.1 |
||||||||||
|
Display dry contact status.
close(0) represents door close. open(1) represents door open. not-attached(2) represents door sensor don't attach to device. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.2 |
||||||||||
|
Dry contact Type Selection
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.3 |
outletCAPTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2
·
1 row entry
·
2 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk outletCAPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::outletCAPTable'
Outlet CAP table
Outlet CAP entry containing CAP info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of outlet's CAP configuration
|
Integer32 Constraints: range: 1-40 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1.1 |
|
Display or set the CAP Priority of outlet.
Priority 0 means this outlet does not support this OID. |
Integer32r/w Constraints: range: 0-99 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1.2 |
deviceIntegerValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.99
·
1 row entry
·
5 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk deviceIntegerValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::deviceIntegerValueTable'
Device value table. This table displays device's current, voltage, power and power dissipation.
Single deviceValue entry containing device info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of deviceValue.
|
Integer32 Constraints: range: 1-1 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.1 |
|
Device electric current value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.2 |
|
Device voltage value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.3 |
|
Device power value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.4 |
|
Device power dissipation value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.5 |
sensorIntegerValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.100
·
1 row entry
·
4 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk sensorIntegerValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::sensorIntegerValueTable'
Device's sensor value table. This table displays sensor's temperature, humidity and pressure.
Single device's sensor value entry containing device info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of sensor number.
|
Integer32 Constraints: range: 1-6 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.1 |
|
Sensor's Temperature value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.2 |
|
Sensor's Humidity value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.3 |
|
Sensor's Pressure value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.4 |
outletValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.2.1
·
1 row entry
·
7 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk outletValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::outletValueTable'
Display total outlet value table
Single outletValue entry containing outlet info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of outlet number
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.1 |
|
Outlet electric current value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.2 |
|
Outlet voltage value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.3 |
|
Outlet power value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.4 |
|
Outlet power dissipation value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.5 |
|
Outlet Max Current value. unit: (A).
If the device does not support this OID, we show value 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.6 |
|
Outlet Power Factor value.
If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.7 |
outletConfigTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.2.10
·
1 row entry
·
16 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk outletConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::outletConfigTable'
Outlet configuration table
Outlet Config entry containing outlet info.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Index of outlet number
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.1 |
||||||||
|
Display or set the name of outlet.
If the device does not support this OID, we show n/a. string length: 0~48 NOTE: Input string as /empty to set this object to NULL. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.2 |
||||||||
|
Display or set the confirmation of outlet.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.3 |
||||||||
|
Display or set the ON delay time of outlet.
When this model does not support the OID, we show value -1. |
Integer32r/w Constraints: range: -1-999 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.4 |
||||||||
|
Display or set the OFF delay time of outlet.
When this model does not support the OID, we show value -1. |
Integer32r/w Constraints: range: -1-999 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.5 |
||||||||
|
Display or set the shutdown mehtod of outlet.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.6 |
||||||||
|
Display or set the MAC address of ShutdownMethod.
If the device does not support this OID, we show n/a. string length: 12 |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.7 |
||||||||
|
Display or set the outlet minimum electric current measurment threshold.
Example: range 0.0 ~16.0 rerpresnts 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device d… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.8 |
||||||||
|
Display or set the outlet maximum electric current measurment threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device d… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.9 |
||||||||
|
Display or set the outlet minimum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does … |
Integer32r/w Constraints: range: 900-2600range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.10 |
||||||||
|
Display or set the outlet maximum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does … |
Integer32r/w Constraints: range: 900-2600range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.11 |
||||||||
|
Display or set the outlet minimum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.12 |
||||||||
|
Display or set the outlet maximum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.13 |
||||||||
|
Display or set the outlet maximum power dissipation measurment threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the d… |
Integer32r/w Constraints: range: 0-999990range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.14 |
||||||||
|
Whether local access of Outlet is locked by remote or not.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.15 |
||||||||
|
Whether the outlet is always ON or not.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.16 |
outletSwitchableTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.2.70
·
1 row entry
·
2 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk outletSwitchableTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::outletSwitchableTable'
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index of outlet number.
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1.1 |
||||
| Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1.2 |
outletIntegerValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.2.99
·
1 row entry
·
5 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk outletIntegerValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::outletIntegerValueTable'
Display total outlet value table
Single outletValue entry containing outlet info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of outlet number.
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.1 |
|
Outlet electric current value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.2 |
|
Outlet voltage value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.3 |
|
Outlet power value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.4 |
|
Outlet power dissipation value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.5 |
breakerStatusTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.3.1
·
1 row entry
·
2 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk breakerStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::breakerStatusTable'
Display total bank value table
Single bankValue entry containing bank info.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Index of breaker number.
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1.1 |
||||||
|
Breaker status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1.2 |
bankValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.3.2
·
1 row entry
·
8 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk bankValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::bankValueTable'
Display total bank value table
Single bankValue entry containing bank info.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Index of bank number
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.1 |
||||||||
|
Bank electric current value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.2 |
||||||||
|
Bank voltage value.
We put this OID to write access type for user to set the reference voltage on EC1000 model. And the setting should be the numbers. You can set 0 to clear the setting. If this measurement value is not… |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.3 |
||||||||
|
Bank power value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.4 |
||||||||
|
Bank power dissipation value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.5 |
||||||||
|
The Bank Max Current value. unit: (A)
EC1000:0A~320A |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.6 |
||||||||
|
The status of Energy sensor Bank attached status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.7 |
||||||||
|
Bank Power Factor value.
If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.8 |
bankConfigTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.3.3
·
1 row entry
·
9 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk bankConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::bankConfigTable'
Bank configuration table
Bank Config entry containing Bank info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of bank number
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.1 |
|
Display or set the name of bank.
When this model does not support the OID, we show n/a. string length: 0~15 NOTE: Input string as /empty to set this object to NULL. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.2 |
|
Display or set the outlet minimum electric current measurment threshold.
Example: range 0.0 ~16.0 rerpresnts 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device d… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.3 |
|
Display or set the outlet maximum electric current measurment threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device d… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.4 |
|
Display or set the outlet minimum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does … |
Integer32r/w Constraints: range: 900-2600range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.5 |
|
Display or set the outlet maximum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does … |
Integer32r/w Constraints: range: 900-2600range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.6 |
|
Display or set the outlet minimum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.7 |
|
Display or set the outlet maximum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.8 |
|
Display or set the outlet maximum power dissipation measurment threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the d… |
Integer32r/w Constraints: range: 0-999990range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.9 |
bankControlTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.3.4
·
1 row entry
·
2 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk bankControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::bankControlTable'
Bank Control table
Bank control entry.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Index of bank number
|
Integer32 Constraints: range: 1-4 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1.1 |
||||||||||
|
This function is used for outlet control of bank.
Set off(1) to turn off for outlet control of bank. Set on(2) to turn on for all outlet control of bank. Set reboot(3) to turn on for outlet control of bank. Get this obj… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1.2 |
bankIntegerValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.3.99
·
1 row entry
·
5 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk bankIntegerValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::bankIntegerValueTable'
Display total bank value table
Single bankValue entry containing bank info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of bank number.
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.1 |
|
Bank electric current value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.2 |
|
Bank voltage value.
This value indicates that 1,000 times. We put this OID to write access type for user to set the reference voltage on EC1000 model. And the setting should be the numbers. You can set 0… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.3 |
|
Bank power value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.4 |
|
Bank power dissipation value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.5 |
snmpTrapTable
table.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3
·
1 row entry
·
7 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk snmpTrapTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::snmpTrapTable'
PE SNMP agent trap setup table. If users want to use trap, they must set enable trap, ip and community first.
Single trap entry containing trap receiver info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of trap receiver
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.1 |
|
Trap receiver IP address
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.2 |
|
NMS trap port to be used by agent to send trap
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.3 |
|
If use SNMPv1/v2c to receive trap should set this Community string.
MAX string length: 20 NOTE: Input string as /empty to set this object to NULL. |
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.4 |
|
If use SNMPv3 to receive trap should set this string.
NOTE: Input string as /empty to set this object to NULL. MAX string length: 20 |
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.5 |
|
If use SNMPv3 to receive trap should set this string.
MAX string length: 20 NOTE: Input string as /empty to set this object to NULL. |
OctetStringr/w Constraints: range: 8-20 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.6 |
|
If use SNMPv3 to receive trap should set this string.
MAX string length: 20 NOTE: Input string as /empty to set this object to NULL. |
OctetStringr/w Constraints: range: 8-20 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.7 |
ipFilterTable
table.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3
·
1 row entry
·
3 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk ipFilterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::ipFilterTable'
A list of restricted ip.
Status and parameter values for a PE's restricted IP.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The value of index for the ip filter.
|
Integer32 Constraints: range: 1-5 |
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.1 |
|
A set of restricted ip.
ex. 192.168.0.1 Note: Users must follow in order to set the ip address. Note: To clear the settings to set the ip 0.0.0.0 |
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.2 |
|
A set of restricted ip.
ex. 192.168.0.255 Note: Users must follow in order to set the ip address. Note: To clear the settings to set the ip 0.0.0.0 |
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.3 |
macFilterTable
table.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3
·
1 row entry
·
2 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk macFilterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::macFilterTable'
A list of restricted mac.
Status and parameter values for a PE's restricted MAC.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The value of index for the mac filter.
|
Integer32 Constraints: range: 1-5 |
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1.1 |
|
A set of restricted mac.
string length: 12 ex. 004854655511 Note: Users must follow in order to set the MAC address. Note: To clear the settings to set the MAC 000000000000 |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1.2 |