ATEN-PE-CFG Table View

Table-centric layout grouping table, row, and column objects.

Tables
22
Rows
22
Columns
160

usrListTable

table
.1.3.6.1.4.1.21317.1.3.2.2.1.1 · 1 row entry · 47 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk usrListTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::usrListTable'
A list of user. The number of user is
given by the value of usrcfgNumber.
usrListEntry row .1.3.6.1.4.1.21317.1.3.2.2.1.1.1
Status and parameter values for a pe8208 user.
Indexes
Column Syntax OID
usrIndexThe value of usrIndex for the user. We have 1 administrator and 8 users.
The index 9 will be the administrator.
Integer32
Constraints:
range: 1-9
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.1
usrTypeThe user's type.Enumeration
Enumerated Values:
1administrator
2user
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.2
usrNameA textual string containing name of the user.
string length: 1~16
OctetStringr/w
Constraints:
range: 1-16
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.3
usrPasswordA textual string containing password of the user.
string length: 1~16
OctetStringr/w
Constraints:
range: 1-16
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.4
usrPort1AuthDisplay or set this user's outlet 1 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.5
usrPort2AuthDisplay or set this user's outlet 2 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.6
usrPort3AuthDisplay or set this user's outlet 3 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.7
usrPort4AuthDisplay or set this user's outlet 4 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.8
usrPort5AuthDisplay or set this user's outlet 5 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.9
usrPort6AuthDispaly or set this user's outlet 6 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.10
usrPort7AuthDisplay or set this user's outlet 7 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.11
usrPort8AuthDisplay or set this user's outlet 8 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.12
usrPort9AuthDisplay or set this user's outlet 9 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.13
usrPort10AuthDisplay or set this user's outlet 10 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.14
usrPort11AuthDisplay or set this user's outlet 11 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.15
usrPort12AuthDisplay or set this user's outlet 12 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.16
usrPort13AuthDisplay or set this user's outlet 13 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.17
usrPort14AuthDisplay or set this user's outlet 14 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.18
usrPort15AuthDisplay or set this user's outlet 15 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.19
usrPort16AuthDisplay or set this user's outlet 16 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.20
usrPort17AuthDisplay or set this user's outlet 17 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.21
usrPort18AuthDisplay or set this user's outlet 18 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.22
usrPort19AuthDisplay or set this user's outlet 19 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.23
usrPort20AuthDisplay or set this user's outlet 20 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.24
usrPort21AuthDisplay or set this user's outlet 21 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.25
usrPort22AuthDisplay or set this user's outlet 22 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.26
usrPort23AuthDisplay or set this user's outlet 23 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.27
usrPort24AuthDisplay or set this user's outlet 24 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.28
usrPort25AuthDisplay or set this user's outlet 25 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.29
usrPort26AuthDisplay or set this user's outlet 26 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.30
usrPort27AuthDisplay or set this user's outlet 27 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.31
usrPort28AuthDisplay or set this user's outlet 28 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.32
usrPort29AuthDisplay or set this user's outlet 29 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.33
usrPort30AuthDisplay or set this user's outlet 30 authority.
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.34
usrPort31AuthDisplay or set this user's outlet 31 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.35
usrPort32AuthDisplay or set this user's outlet 32 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.36
usrPort33AuthDisplay or set this user's outlet 33 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.37
usrPort34AuthDisplay or set this user's outlet 34 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.38
usrPort35AuthDisplay or set this user's outlet 35 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.39
usrPort36AuthDisplay or set this user's outlet 36 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.40
usrPort37AuthDisplay or set this user's outlet 37 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.41
usrPort38AuthDisplay or set this user's outlet 38 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.42
usrPort39AuthDisplay or set this user's outlet 39 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.43
usrPort40AuthDisplay or set this user's outlet 40 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.44
usrPort41AuthDisplay or set this user's outlet 41 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.45
usrPort42AuthDisplay or set this user's outlet 42 authority
Port in the pe of series represents outlet.
Port in the Energy monitor of series represents a bank or a pdu.
Enumerationr/w
Enumerated Values:
1disable
2view
3modify
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.46
usrEnableDisplay or set this user is enable or notEnumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.47
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3 · 1 row entry · 9 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk deviceValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::deviceValueTable'
Device value table. This table displays device's current, voltage, power and
power dissipation.
deviceValueEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1
Single deviceValue entry containing device info.
Column Syntax OID
deviceValueIndexIndex of deviceValue.Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.1
deviceCurrentDevice electric current value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.2
deviceVoltageDevice voltage value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.3
devicePowerDevice power value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.4
devicePowerDissipationDevice power dissipation value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.5
inputMaxVoltageDevice input Voltage value. unit:(V)
If the device does not support this OID, we show value 0.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.6
inputMaxCurrentDevice input Current value. unit:(A)
If the device does not support this OID, we show value 0.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.7
powerCapacityDevice power Capacity value.unit:(VA)
If the device does not support this OID, we show value 0.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.8
devicePowerFactorDevice power Factor value.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.9
.1.3.6.1.4.1.21317.1.3.2.2.2.1.4 · 1 row entry · 5 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk sensorValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::sensorValueTable'
Device's sensor value table. This table displays sensor's temperature, humidity and
pressure.
sensorValueEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1
Single device's sensor value entry containing device info.
Column Syntax OID
sensorValueIndexIndex of sensor number.Integer32
Constraints:
range: 1-6
.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.1
sensorTemperatureSensor's Temperature value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.2
sensorHumiditySensor's Humidity value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.3
sensorPressureSensor's Pressure value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.4
sensorPropertySensor's Property.Enumeration
Enumerated Values:
1intake
2exhaust
3floor
.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.5
.1.3.6.1.4.1.21317.1.3.2.2.2.1.5 · 1 row entry · 2 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk deviceOutletStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::deviceOutletStatusTable'
Device outlet status value table.
deviceOutletStatusEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1
Single deviceOutletStatus entry containing device info.
Column Syntax OID
deviceOutletStatusIndexIndex of deviceOutletStatusInteger32
Constraints:
range: 1-30
.1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1.1
displayOutletStatusDisplay outlet status.Enumeration
Enumerated Values:
1off
2on
3pending
4fault
5noauth
6not-support
7pop
.1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1.2
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6 · 1 row entry · 8 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk deviceConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::deviceConfigTable'
Device configuration table
deviceConfigEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1
Single deviceConfig entry containing device info.
Column Syntax OID
deviceConfigIndexIndex of deviceConfigInteger32
Constraints:
range: 1-1
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.1
deviceMinCurMTDisplay or set device minimum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320.
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does …
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.2
deviceMaxCurMTDisplay or set device maximum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device doe…
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.3
deviceMinVolMTDisplay or set device minimum voltage measurement threshold.
Exapmple: range 90.0~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does not…
Integer32r/w
Constraints:
range: 900-2600
range: -3000--3000
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.4
deviceMaxVolMTDisplay or set device maximum voltage measurement threshold.
Example: range 90.0~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does not …
Integer32r/w
Constraints:
range: 900-2600
range: -3000--3000
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.5
deviceMinPMTDisplay or set device minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does not s…
Integer32r/w
Constraints:
range: 0-99999
range: -3000--3000
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.6
deviceMaxPMTDisplay or set device maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does not s…
Integer32r/w
Constraints:
range: 0-99999
range: -3000--3000
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.7
deviceMaxPDMTDisplay or set device maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the dev…
Integer32r/w
Constraints:
range: 0-999990
range: -3000--3000
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.8
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7 · 1 row entry · 7 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk deviceSensorTresholdTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::deviceSensorTresholdTable'
Device environment value table
deviceSensorTresholdEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1
Device's sensor Environment entry containing sensor info.
Column Syntax OID
deviceSensorTresholdIndexIndex of sensor numberInteger32
Constraints:
range: 1-6
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.1
sensorMinTempMTDisplay or set sensor minimum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device doe…
Integer32r/w
Constraints:
range: -200-600
range: -3000--3000
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.2
sensorMaxTempMTDisplay or set sensor maximum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device doe…
Integer32r/w
Constraints:
range: -200-600
range: -3000--3000
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.3
sensorMinHumMTDisplay or set sensor minimum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does not…
Integer32r/w
Constraints:
range: 100-950
range: -3000--3000
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.4
sensorMaxHumMTDisplay or set sensor maximum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does not…
Integer32r/w
Constraints:
range: -3000--3000
range: 100-950
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.5
sensorMinPressMTDisplay or set sensor minimum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device …
Integer32r/w
Constraints:
range: -2500-2500
range: -3000--3000
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.6
sensorMaxPressMTDisplay or set sensor maximum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device …
Integer32r/w
Constraints:
range: -2500-2500
range: -3000--3000
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.7
.1.3.6.1.4.1.21317.1.3.2.2.2.1.15 · 1 row entry · 3 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk dryContactTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::dryContactTable'
Device's Dry Contact table.
dryContactEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1
Single device's dry contact value entry containing device info.
Indexes
Column Syntax OID
dryContactIndexIndex of dry contact number.Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.1
dryContactStatusDisplay dry contact status.
close(0) represents door close.
open(1) represents door open.
not-attached(2) represents door sensor don't attach to device.
Enumeration
Enumerated Values:
0close
1open
2not-attached
10not-support
.1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.2
dryContactTypeDry contact Type SelectionEnumerationr/w
Enumerated Values:
0notinstalled
1photo
2inductiveproximity
3reed
10not-support
.1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.3
.1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2 · 1 row entry · 2 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk outletCAPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::outletCAPTable'
Outlet CAP table
outletCAPEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1
Outlet CAP entry containing CAP info.
Indexes
Column Syntax OID
outletCAPIndexIndex of outlet's CAP configurationInteger32
Constraints:
range: 1-40
.1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1.1
outletCAPPriorityDisplay or set the CAP Priority of outlet.
Priority 0 means this outlet does not support this OID.
Integer32r/w
Constraints:
range: 0-99
.1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1.2
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99 · 1 row entry · 5 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk deviceIntegerValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::deviceIntegerValueTable'
Device value table. This table displays device's current, voltage, power and
power dissipation.
deviceIntegerValueEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1
Single deviceValue entry containing device info.
Column Syntax OID
deviceIntegerValueIndexIndex of deviceValue.Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.1
deviceIntegerCurrentDevice electric current value.
This value indicates that 1,000 times.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.2
deviceIntegerVoltageDevice voltage value.
This value indicates that 1,000 times.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.3
deviceIntegerPowerDevice power value.
This value indicates that 1,000 times.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.4
deviceIntegerPowerDissipationDevice power dissipation value.
This value indicates that 1,000 times.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.5
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100 · 1 row entry · 4 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk sensorIntegerValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::sensorIntegerValueTable'
Device's sensor value table. This table displays sensor's temperature, humidity and
pressure.
sensorIntegerValueEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1
Single device's sensor value entry containing device info.
Column Syntax OID
sensorIntegerValueIndexIndex of sensor number.Integer32
Constraints:
range: 1-6
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.1
sensorIntegerTemperatureSensor's Temperature value.
This value indicates that 1,000 times.
If this measurement value is not available, it returns value -1000000.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.2
sensorIntegerHumiditySensor's Humidity value.
This value indicates that 1,000 times.
If this measurement value is not available, it returns value -1000000.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.3
sensorIntegerPressureSensor's Pressure value.
This value indicates that 1,000 times.
If this measurement value is not available, it returns value -1000000.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.4
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1 · 1 row entry · 7 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk outletValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::outletValueTable'
Display total outlet value table
outletValueEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1
Single outletValue entry containing outlet info.
Column Syntax OID
outletValueIndexIndex of outlet numberInteger32
Constraints:
range: 1-30
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.1
outletCurrentOutlet electric current value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.2
outletVoltageOutlet voltage value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.3
outletPowerOutlet power value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.4
outletPowerDissipationOutlet power dissipation value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.5
outletMaxCurrentOutlet Max Current value. unit: (A).
If the device does not support this OID, we show value 0.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.6
outletPowerFactorOutlet Power Factor value.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.7
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10 · 1 row entry · 16 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk outletConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::outletConfigTable'
Outlet configuration table
outletConfigEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1
Outlet Config entry containing outlet info.
Column Syntax OID
outletConfigIndexIndex of outlet numberInteger32
Constraints:
range: 1-30
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.1
outletNameDisplay or set the name of outlet.
If the device does not support this OID, we show n/a.
string length: 0~48
NOTE: Input string as /empty to set this object to NULL.
RFC1213-MIBDisplayStringr/w.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.2
outletConfirmationDisplay or set the confirmation of outlet.Enumerationr/w
Enumerated Values:
1no
2yes
3noauth
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.3
outletOnDelayTimeDisplay or set the ON delay time of outlet.
When this model does not support the OID, we show value -1.
Integer32r/w
Constraints:
range: -1-999
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.4
outletOffDelayTimeDisplay or set the OFF delay time of outlet.
When this model does not support the OID, we show value -1.
Integer32r/w
Constraints:
range: -1-999
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.5
outletShutdownMethodDisplay or set the shutdown mehtod of outlet.Enumerationr/w
Enumerated Values:
1kill-the-power
2wake-on-lan
3after-ac-back
4not-support
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.6
outletMACDisplay or set the MAC address of ShutdownMethod.
If the device does not support this OID, we show n/a.
string length: 12
RFC1213-MIBDisplayStringr/w.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.7
outletMinCurMTDisplay or set the outlet minimum electric current measurment threshold.
Example: range 0.0 ~16.0 rerpresnts 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device d…
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.8
outletMaxCurMTDisplay or set the outlet maximum electric current measurment threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device d…
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.9
outletMinVolMTDisplay or set the outlet minimum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does …
Integer32r/w
Constraints:
range: 900-2600
range: -3000--3000
range: -2000000--2000000
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.10
outletMaxVolMTDisplay or set the outlet maximum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does …
Integer32r/w
Constraints:
range: 900-2600
range: -3000--3000
range: -2000000--2000000
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.11
outletMinPMTDisplay or set the outlet minimum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does not…
Integer32r/w
Constraints:
range: 0-99999
range: -3000--3000
range: -2000000--2000000
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.12
outletMaxPMTDisplay or set the outlet maximum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does not…
Integer32r/w
Constraints:
range: 0-99999
range: -3000--3000
range: -2000000--2000000
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.13
outletMaxPDMTDisplay or set the outlet maximum power dissipation measurment threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the d…
Integer32r/w
Constraints:
range: 0-999990
range: -3000--3000
range: -2000000--2000000
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.14
outletLocalAccessLockWhether local access of Outlet is locked by remote or not.Enumerationr/w
Enumerated Values:
1unlocked
2locked
3not-support
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.15
outletAlwaysONWhether the outlet is always ON or not.Enumerationr/w
Enumerated Values:
1no
2yes
3not-support
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.16
.1.3.6.1.4.1.21317.1.3.2.2.2.2.70 · 1 row entry · 2 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk outletSwitchableTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::outletSwitchableTable'
outletSwitchableEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1
Column Syntax OID
outletSwitchableIndexIndex of outlet number.Integer32
Constraints:
range: 1-30
.1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1.1
outletSwitchableEnumeration
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1.2
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99 · 1 row entry · 5 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk outletIntegerValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::outletIntegerValueTable'
Display total outlet value table
outletIntegerValueEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1
Single outletValue entry containing outlet info.
Column Syntax OID
outletIntegerValueIndexIndex of outlet number.Integer32
Constraints:
range: 1-30
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.1
outletIntegerCurrentOutlet electric current value.
This value indicates that 1,000 times.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.2
outletIntegerVoltageOutlet voltage value.
This value indicates that 1,000 times.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.3
outletIntegerPowerOutlet power value.
This value indicates that 1,000 times.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.4
outletIntegerPowerDissipationOutlet power dissipation value.
This value indicates that 1,000 times.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.5
.1.3.6.1.4.1.21317.1.3.2.2.2.3.1 · 1 row entry · 2 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk breakerStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::breakerStatusTable'
Display total bank value table
breakerStatusEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1
Single bankValue entry containing bank info.
Column Syntax OID
breakerStatusIndexIndex of breaker number.Integer32
Constraints:
range: 1-30
.1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1.1
breakerStatusBreaker status.Enumeration
Enumerated Values:
1off
2on
3not-support
.1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1.2
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2 · 1 row entry · 8 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk bankValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::bankValueTable'
Display total bank value table
bankValueEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1
Single bankValue entry containing bank info.
Indexes
Column Syntax OID
bankValueIndexIndex of bank numberInteger32
Constraints:
range: 1-30
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.1
bankCurrentBank electric current value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.2
bankVoltageBank voltage value.
We put this OID to write access type for user to set the reference voltage on EC1000 model.
And the setting should be the numbers. You can set 0 to clear the setting.
If this measurement value is not…
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.3
bankPowerBank power value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.4
bankPowerDissipationBank power dissipation value.
If this measurement value is not available, it returns: N/A.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.5
bankMaxCurrentThe Bank Max Current value. unit: (A)
EC1000:0A~320A
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.6
bankAttachStatusThe status of Energy sensor Bank attached status.Enumeration
Enumerated Values:
1noattached
2attached
3error
4noexisted
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.7
bankPowerFactorBank Power Factor value.
If the device does not support this OID, it returns: not-support.
RFC1213-MIBDisplayString.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.8
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3 · 1 row entry · 9 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk bankConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::bankConfigTable'
Bank configuration table
bankConfigEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1
Bank Config entry containing Bank info.
Indexes
Column Syntax OID
bankConfigIndexIndex of bank numberInteger32
Constraints:
range: 1-30
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.1
bankNameDisplay or set the name of bank.
When this model does not support the OID, we show n/a.
string length: 0~15
NOTE: Input string as /empty to set this object to NULL.
RFC1213-MIBDisplayStringr/w.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.2
bankMinCurMTDisplay or set the outlet minimum electric current measurment threshold.
Example: range 0.0 ~16.0 rerpresnts 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device d…
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.3
bankMaxCurMTDisplay or set the outlet maximum electric current measurment threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device d…
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.4
bankMinVolMTDisplay or set the outlet minimum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does …
Integer32r/w
Constraints:
range: 900-2600
range: -3000--3000
range: -2000000--2000000
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.5
bankMaxVolMTDisplay or set the outlet maximum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does …
Integer32r/w
Constraints:
range: 900-2600
range: -3000--3000
range: -2000000--2000000
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.6
bankMinPMTDisplay or set the outlet minimum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does not…
Integer32r/w
Constraints:
range: 0-99999
range: -3000--3000
range: -2000000--2000000
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.7
bankMaxPMTDisplay or set the outlet maximum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the device does not…
Integer32r/w
Constraints:
range: 0-99999
range: -3000--3000
range: -2000000--2000000
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.8
bankMaxPDMTDisplay or set the outlet maximum power dissipation measurment threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the d…
Integer32r/w
Constraints:
range: 0-999990
range: -3000--3000
range: -2000000--2000000
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.9
.1.3.6.1.4.1.21317.1.3.2.2.2.3.4 · 1 row entry · 2 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk bankControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::bankControlTable'
Bank Control table
bankControlEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1
Bank control entry.
Column Syntax OID
bankControlIndexIndex of bank numberInteger32
Constraints:
range: 1-4
.1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1.1
bankControlStatusThis function is used for outlet control of bank.
Set off(1) to turn off for outlet control of bank.
Set on(2) to turn on for all outlet control of bank.
Set reboot(3) to turn on for outlet control of bank.
Get this obj…
Enumerationr/w
Enumerated Values:
1off
2on
3reboot
4nostatus
5not-support
.1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1.2
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99 · 1 row entry · 5 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk bankIntegerValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::bankIntegerValueTable'
Display total bank value table
bankIntegerValueEntry row .1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1
Single bankValue entry containing bank info.
Column Syntax OID
bankIntegerValueIndexIndex of bank number.Integer32
Constraints:
range: 1-30
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.1
bankIntegerCurrentBank electric current value.
This value indicates that 1,000 times.
If this measurement value is not available, it returns value -1000000.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.2
bankIntegerVoltageBank voltage value.
This value indicates that 1,000 times.

We put this OID to write access type for user to set the reference voltage on EC1000 model.
And the setting should be the numbers. You can set 0…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.3
bankIntegerPowerBank power value.
This value indicates that 1,000 times.
If this measurement value is not available, it returns value -1000000.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.4
bankIntegerPowerDissipationBank power dissipation value.
This value indicates that 1,000 times.
If this measurement value is not available, it returns value -1000000.
If the device does not support this OID, it returns value -2000000.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.5
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3 · 1 row entry · 7 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk snmpTrapTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::snmpTrapTable'
PE SNMP agent trap setup table. If users want to use trap, 
they must set enable trap, ip and community first.
snmpTrapEntry row .1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1
Single trap entry containing trap receiver info.
Column Syntax OID
trapReceiverNumberIndex of trap receiverInteger32
Constraints:
range: 1-2
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.1
trapReceiverIPAddressTrap receiver IP addressRFC1155-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.2
trapPortNMS trap port to be used by agent to send trapInteger32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.3
trapCommunityIf use SNMPv1/v2c to receive trap should set this Community string.
MAX string length: 20
NOTE: Input string as /empty to set this object to NULL.
OctetStringr/w
Constraints:
range: 0-20
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.4
trapUsernameIf use SNMPv3 to receive trap should set this string.
NOTE: Input string as /empty to set this object to NULL.
MAX string length: 20
OctetStringr/w
Constraints:
range: 0-20
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.5
trapAuthpasswordIf use SNMPv3 to receive trap should set this string.
MAX string length: 20
NOTE: Input string as /empty to set this object to NULL.
OctetStringr/w
Constraints:
range: 8-20
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.6
trapPrivpasswordIf use SNMPv3 to receive trap should set this string.
MAX string length: 20
NOTE: Input string as /empty to set this object to NULL.
OctetStringr/w
Constraints:
range: 8-20
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.7
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3 · 1 row entry · 3 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk ipFilterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::ipFilterTable'
A list of restricted ip.
ipFilterEntry row .1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1
Status and parameter values for a PE's restricted IP.
Indexes
Column Syntax OID
ipFilterIndexThe value of index for the ip filter.Integer32
Constraints:
range: 1-5
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.1
ipFilterFromA set of restricted ip.
ex. 192.168.0.1

Note: Users must follow in order to set the ip address.
Note: To clear the settings to set the ip 0.0.0.0
RFC1155-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.2
ipFilterToA set of restricted ip.
ex. 192.168.0.255

Note: Users must follow in order to set the ip address.
Note: To clear the settings to set the ip 0.0.0.0
RFC1155-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.3
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3 · 1 row entry · 2 columns
Uses the aten variant from /opt/observium/mibs/aten.
Command help
Walk macFilterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE-CFG::macFilterTable'
A list of restricted mac.
macFilterEntry row .1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1
Status and parameter values for a PE's restricted MAC.
Indexes
Column Syntax OID
macFilterIndexThe value of index for the mac filter.Integer32
Constraints:
range: 1-5
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1.1
macFilterSetA set of restricted mac.
string length: 12
ex. 004854655511

Note: Users must follow in order to set the MAC address.
Note: To clear the settings to set the MAC 000000000000
RFC1213-MIBDisplayStringr/w.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1.2