ARUBAWIRED-POWERSUPPLY-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
11
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1 · 1 row entry · 11 columns
Uses the aruba variant from /opt/observium/mibs/aruba.
Command help
Walk arubaWiredPowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ARUBAWIRED-POWERSUPPLY-MIB' -M '/opt/observium/mibs/aruba:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ARUBAWIRED-POWERSUPPLY-MIB::arubaWiredPowerSupplyTable'
This table contains one row per switch power supply entity.
arubaWiredPowerSupplyEntry row .1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1
Information about the power supply physical entity table.
Column Syntax OID
This variable uniquely identifies the group containing the
power supply. Group means chassis in the stack and the value
1 MUST be used for non-modular devices.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.1
This variable uniquely identifies the power supply in a
chassis and value 1 must be used for non-modular devices.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.2
Identification of the power supply for the system.
SNMPv2-TCDisplayString
Constraints:
range: 0-20
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.3
Current status for the power supply.
SNMPv2-TCDisplayString
Constraints:
range: 0-20
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.4
Power supply product name identification. This field is used
to determine if the power supply is supported.
SNMPv2-TCDisplayString
Constraints:
range: 0-20
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.5
Power supply serial number to uniquely identify the power
supply.
SNMPv2-TCDisplayString
Constraints:
range: 0-20
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.6
Total instantaneous power supplied by the power supply in
Watts.
WattsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.7
Total maximum power capacity that can be supplied by the
power supply in Watts.
WattsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.8
Number of failures the power supply has experienced since the
most recent insertion of the power supply and boot of the
system. The number of failures for a power supply will be
cleared if the power supply is removed f…
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.9
Power Supply airflow direction.
SNMPv2-TCDisplayString
Constraints:
range: 0-20
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.10
Current status for the power supply as an enumerated value.
Enumeration
Enumerated Values:
1ok
2faultAbsent
3faultInput
4faultOutput
5faultPOE
6faultNoRecov
7alert
8unknown
9unsupported
10warning
11init
12empty
13faultAirflow
14faultRedundancy
15faultMixedInput
16overvoltage
17undervoltage
.1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.11