ALU-POWER-ETHERNET-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
22
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1 · 1 row entry · 13 columns
Uses the alcatel variant from /opt/observium/mibs/alcatel.
Command help
Walk pethPsePortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ALU-POWER-ETHERNET-MIB' -M '/opt/observium/mibs/alcatel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ALU-POWER-ETHERNET-MIB::pethPsePortTable'
A table of objects that display and control the power
characteristics power Ethernet ports on a Power Source
Entity (PSE) device. This group will be implemented in
managed power Ethernet switches and mid-span devices.
pethPsePortEntry row .1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1
A set of objects that display and control the power
characteristics of a power Ethernet PSE port.
Column Syntax OID
This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is connected.
Group means box in the stack, module in a rack and the value 1
MUST be used for non-modular devices .
pethPseMi…
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.1
This variable uniquely identifies the power Ethernet PSE
port within group pethPseGroupIndex to which the
power Ethernet PSE entry is connected.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.2
Enables power supply on this port.
Setting this object at a value enable(1) enables power
and detection mechanism for this port.
Setting this object at a value disable(2) disables power
for this port.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.3
Describes the capability of controlling the power pairs
functionality to switch pins for sourcing power.
The value true indicate that the device has the capability
to control the power pairs
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.4
Describes or controls the pairs in use. If the value of
pethPsePortPowerPairsControl is true, this object is
writable.
A value of signal(1) means that the signal pairs
only are in use.
A value of spare(2) means that the…
Enumerationr/w
Enumerated Values:
1signal
2spare
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.5
Controls the power detection mechanism of the port.
Setting the value auto(1) enables the power detection
mechanism of the port.
Setting the value test(2) puts the port in a
testmode: force continuous discovery without …
Enumerationr/w
Enumerated Values:
1auto
2test
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.6
Describes the operational status of the port PD detection.
A value of disabled(1)- indicates that the PSE State diagram is in
the state IDLE
A value of searching(2)- indicates that the PSE State diagram is in
the state …
Enumeration
Enumerated Values:
1disabled
2searching
4deliveringPower
5fault
7test
8denyLowPriority
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.7
This object controls the priority of the port from the point
of view of a power management algorithm. The priority that
is set by this variable could be used by a control mechanism
that prevents over current situations …
Enumerationr/w
Enumerated Values:
1critical
2high
3low
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.8
The value ok(1) indicates the Power Maintenance
Signature is present and the overcurrent condition has not been
detected.
The value overCurrent (2) indicates an overcurrent condition
has been detected.
The value mPSAbse…
Enumeration
Enumerated Values:
1ok
2underCurrent
3mPSAbsent
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.10
Counts the number of times that the
pethPsePortPowerMaintenanceStatus attribute changes from any
value to the value mPSAbsent(3).
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.11
Counts the number of times that the aPSEPowerCurrentStatus
attribute changes from any value to the value overCurrent(2).
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.12
A manager will set the value of this variable to a value
that indicates the type of the device that is connected
to theport. This value can be the result of the mapping
the address of the station connected to the port a…
Enumerationr/w
Enumerated Values:
1other
2telephone
3webcam
4wireless
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.13
Classification is a way to tag different terminals on the
Power over LAN network according to their power consumption.
Devices such as IP telephones, WLAN access points and others,
will be classified according to their …
Enumeration
Enumerated Values:
1class0
2class1
3class2
4class3
5class4
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.14
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.2 · 1 row entry · 2 columns
Uses the alcatel variant from /opt/observium/mibs/alcatel.
Command help
Walk pethPdPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ALU-POWER-ETHERNET-MIB' -M '/opt/observium/mibs/alcatel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ALU-POWER-ETHERNET-MIB::pethPdPortTable'
A table of objects that display and control the power
characteristics power Ethernet ports on a Powered
Device(PD) device. This group will be implemented in
managed powered and mid-span devices.
pethPdPortEntry row .1.3.6.1.4.1.6486.800.1.2.1.27.999.1.2.1
A set of objects that display and control the power
characteristics of a Powered Device port.
Indexes
Column Syntax OID
An index value that uniquely identifies an
interface to a PD device. The
interface identified by a particular value of
this index is the same interface as identified
by the same value of ifIndex. The mapping
between th…
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.2.1.1
This value identifies the operational state of the PD functions.
An interface which can provide the PD functions will be enabled
to do so when this attribute has the value enable. When this
attribute has the value disa…
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.2.1.2
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1 · 1 row entry · 5 columns
Uses the alcatel variant from /opt/observium/mibs/alcatel.
Command help
Walk pethMainPseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ALU-POWER-ETHERNET-MIB' -M '/opt/observium/mibs/alcatel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ALU-POWER-ETHERNET-MIB::pethMainPseTable'
A table of objects that display and control the Main power
on a PSE  device. Example - an Ethernet switch midspan device can
  control an Ethnternet port and the Main Power supply unit's.
pethMainPseEntry row .1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1
A set of objects that display and control the Main power
of a PSE.
Column Syntax OID
This variable uniquely identifies the group to which
power Ethernet PSE is connected.Group means (box in the stack,
module in a rack) and the value 1 MUST be used for non-modular
devices
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1.1
The nominal power of the PSE expressed in Watts.
WattsUnsigned32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1.2
The operational status of the main PSE.
Enumeration
Enumerated Values:
1on
2off
3faulty
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1.3
Measured usage power expressed in Watts.
WattsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1.4
The usage threshold expressed in percents for
comparing the measured power and initiating
an alarm if the threshold is exceeded.
%Integer32r/w
Constraints:
range: 1-99
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1.7
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.4.1 · 1 row entry · 2 columns
Uses the alcatel variant from /opt/observium/mibs/alcatel.
Command help
Walk pethNotificationControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ALU-POWER-ETHERNET-MIB' -M '/opt/observium/mibs/alcatel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ALU-POWER-ETHERNET-MIB::pethNotificationControlTable'
A table of objects that display and control the Notification
on a PSE  device.
pethNotificationControlEntry row .1.3.6.1.4.1.6486.800.1.2.1.27.999.1.4.1.1
A set of objects that control the Notification events.
Column Syntax OID
This variable uniquely identifies the group. Group means
box in the stack, module in a rack and it is RECOMENDED
that the value 1 be used for non-modular devices
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.6486.800.1.2.1.27.999.1.4.1.1.1
Enable Notification from Agent
Enumerationr/w
Enumerated Values:
1enable
2disable