Indication that the IMA Link IDs are
received out of order on the links in the
network feed IMA group.
adGenMiniDslamImaLinksOutOfOrderCleared
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.12
Indication that the IMA Link IDs are
received in order on the links in the
network feed IMA group that were
previously out of order.
adGenMiniDslamConfigErrorActive
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.13
Indication that a problem occured while
a config restore or save was attempted.
Points to a flash/filesystem problem.
adGenMiniDslamConfigErrorCleared
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.14
Indication that a new config file
has been written to replace the
faulty one.
adGenMiniDslamCircuitIdChange
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.15
Indication that the customer use OID (aka Circuit ID) was
changed for the referenced port.
adGenMiniDslamSpanPowerFailureActive
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.16
A loss of span power was detected on a span power
channel. The varbind adGenMiniDslam3gSpanPowerChannel
indicates which channel was responsible for
the condition.
adGenMiniDslamSpanPowerFailureCleared
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.17
A loss of span power alarm was cleared on a span power
channel. The varbind adGenMiniDslam3gSpanPowerChannel
indicates which channel was responsible for
the condition.
adGenMiniDslam3gFanFailureInactive
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.2
Equipment fan failure alarm cleared.
adGenMiniDslam3gFanTrayRemoved
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.3
Fan tray removed from equipment.
adGenMiniDslam3gFanTrayInserted
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.4
Fan tray inserted into equipment.
adGenMiniDslam3gUserTempActive
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.5
Sent when the temperature crosses the
user defined threshold.
adGenMiniDslam3gUserTempCleared
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.6
Sent when the temperature returns to
below the user defined threshold.
adGenMiniDslam3gCriticalHiTempActive
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.7
Indication that temperature had reached the
critical threshold.
adGenMiniDslam3gCriticalHiTempCleared
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.8
Indication that the temperature has
returned to normal operating range.
adGenMiniDslamDspWarmStart
.1.3.6.1.4.1.664.6.10000.61.5.1.1.2.0.9
Indication that a DSP has reset on the referenced
3g. The reason contains the DSP number.