ADTRAN-TAESCUAUTOUPGRADE-MIB

        This MIB defines the objects for the genescu MIB.
    

Imported Objects

adGenSlotProdSwVersion, adGenSlotProdName, adGenSlotInfoIndexADTRAN-GENSLOT-MIB
adTrapInformSeqNumADTRAN-GENTRAPINFORM-MIB
adTAeSCUmg, adTAeSCUmgNotificationEvents, adTAeSCUADTRAN-TAeSCU-MIB
sysNameSNMPv2-MIB
OBJECT-TYPE, MODULE-IDENTITY, Integer32, NOTIFICATION-TYPE, OBJECT-IDENTITYSNMPv2-SMI
DisplayStringSNMPv2-TC

Objects

adTAeSCUAutoUpgradeMgmt .1.3.6.1.4.1.664.2.241.11
adTAeScuAutoUpgradeInitiate .1.3.6.1.4.1.664.2.241.11.1
adTAeSCUAutoUpgradeStatusTable .1.3.6.1.4.1.664.2.241.11.10
adTAeSCUAutoUpgradeStatusEntry
.1.3.6.1.4.1.664.2.241.11.10.1
adTAeScuAutoUpgradeStatus .1.3.6.1.4.1.664.2.241.11.10.1.1
adTAeScuAutoUpgradeSWVerErrLevel .1.3.6.1.4.1.664.2.241.11.11
adTAeScuAutoUpgradeCancel .1.3.6.1.4.1.664.2.241.11.2
adTAeScuAutoUpgradeRetries .1.3.6.1.4.1.664.2.241.11.3
adTAeScuAutoUpgradeRefeshInterval .1.3.6.1.4.1.664.2.241.11.4
adTAeScuAutoUpgradeMode .1.3.6.1.4.1.664.2.241.11.5
adTAeScuAutoUpgradeConfigFilename .1.3.6.1.4.1.664.2.241.11.6
adTAeScuAutoUpgradeBasePath .1.3.6.1.4.1.664.2.241.11.7
adTAeScuAutoUpgradeInvalidate .1.3.6.1.4.1.664.2.241.11.8
adTAeScuAutoUpgradeSystemRelease
.1.3.6.1.4.1.664.2.241.11.9

Notifications/Traps

NameOIDDescription
adTAeSCUAutoUpgradeConfigChanged


.1.3.6.1.4.1.664.1.241.0.24150
is used to indicate that a change in the Auto
Upgrade configuration file has been detected.
adTAeSCUAutoUpgradeInvalidConfigFile


.1.3.6.1.4.1.664.1.241.0.24152
is used to indicate that a problem with the
Auto Upgrade configuration file has been detected, such
as a TFTP error while retrieving the file, or an error
during parsing.  The EMS should perform a 'get' on the
AdTAeScuAutoUpgradeStatus OID for further information
regarding the error condition.
adTAeSCUAutoUpgradeModuleUpgradeStarted



.1.3.6.1.4.1.664.1.241.0.24154
is used to indicate that a module upgrade
operation has been started.
adTAeSCUAutoUpgradeModuleUpgradeCompleted



.1.3.6.1.4.1.664.1.241.0.24156
is used to indicate that a module upgrade
operation has successfully completed.
adTAeSCUAutoUpgradeModuleUpgradeFailed




.1.3.6.1.4.1.664.1.241.0.24158
is used to indicate that a module upgrade
operation has failed.  The EMS should perform a 'get'
on the AdTAeScuAutoUpgradeStatus OID for further
information regarding the error condition.
adTAeSCUAutoUpgradeUnknownModule



.1.3.6.1.4.1.664.1.241.0.24160
is used to indicate that a module
is not present in the Auto Upgrade configuration
file.  This module cannot be upgrade by the Auto
Upgrade system.
adTAAUSoftwareVerErrorClear






.1.3.6.1.4.1.664.1.241.0.24166
Auto Upgrade Software Version Error
adTAAUSoftwareVerErrorActive






.1.3.6.1.4.1.664.1.241.0.24167
Auto Upgrade Software Version Error