ADTRAN-TA5000-THERMAL-MGMT-MIB

        Total Access 5000 Thermal Management MIB
    

Imported Objects

adGenSlotInfoIndexADTRAN-GENSLOT-MIB
adTa5kThermalManagement, adTa5kThermalManagementIDADTRAN-GENTA5K-MIB
adTrapInformSeqNumADTRAN-GENTRAPINFORM-MIB
adIdentity, adProducts, adMgmtADTRAN-MIB
ifIndexIF-MIB
sysNameSNMPv2-MIB
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32SNMPv2-SMI
DisplayString, TruthValueSNMPv2-TC

Objects

adTA5kThermalMgmtmg .1.3.6.1.4.1.664.5.67.1.39.1
adTA5kThermal .1.3.6.1.4.1.664.5.67.1.39.1.1
adTA5kThermalSlotTable .1.3.6.1.4.1.664.5.67.1.39.1.1.1
adTA5kThermalSlotEntry
.1.3.6.1.4.1.664.5.67.1.39.1.1.1.1
adTA5kThermalSlotNumSensors .1.3.6.1.4.1.664.5.67.1.39.1.1.1.1.1
adTA5kThermalManagementTable .1.3.6.1.4.1.664.5.67.1.39.1.1.2
adTA5kThermalManagementEntry
.1.3.6.1.4.1.664.5.67.1.39.1.1.2.1
adTA5kThermalManagementSensorId .1.3.6.1.4.1.664.5.67.1.39.1.1.2.1.1
adTA5kThermalManagementSensorName
.1.3.6.1.4.1.664.5.67.1.39.1.1.2.1.2
adTA5kThermalManagementSensorCurrTemp .1.3.6.1.4.1.664.5.67.1.39.1.1.2.1.3
adTA5kThermalEventsFix .1.3.6.1.4.1.664.5.67.1.39.2
adTa5kThermalEvents .1.3.6.1.4.1.664.5.67.1.39.2.0
adTa5kThermalMgmtModuleIdentity .1.3.6.1.4.1.664.6.10000.67.1.39.1

Notifications/Traps

NameOIDDescription
adTA5kSlotCriticalTempActive




.1.3.6.1.4.1.664.5.67.1.39.2.0.1
indicates that the critical temperature threshold for the
card has been reached. Indicates whether or not equipment is in danger
of shutting down, shedding power, or otherwise due to a critical high 
temperature condition. The equipment will take appropriate actions to 
protect the hardware from damage.
adTA5kSlotCriticalTempClear




.1.3.6.1.4.1.664.5.67.1.39.2.0.2
indicates that the critical temperature condition previously
declared for this card has now cleared.
adTa5kRemoteDeviceCriticalTempActive



.1.3.6.1.4.1.664.5.67.1.39.2.0.3
indicates that the critical temperature threshold for the
remote device has been reached. Indicates whether or not equipment is
in danger of shutting down, shedding power, or otherwise due to a
critical high temperature condition. The equipment will take
appropriate actions to protect the hardware from damage.
adTa5kRemoteDeviceCriticalTempClear



.1.3.6.1.4.1.664.5.67.1.39.2.0.4
indicates that the critical temperature condition previously
declared for this device has now cleared.