ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB

        The MIB module defines over-temperature configuration information and traps for AdtranOS products.
    
Source file
ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB
Last revised
Identity
adGenAOSOverTempProtectionMib
Base OID
1.3.6.1.4.1.664.6.10000.53.1.10
Imported Objects
ADTRAN-AOS adGenAOSCommon adGenAOSConformance
ADTRAN-MIB adIdentity
SNMPv2-CONF MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page)
SNMPv2-SMI MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page)
Net-SNMP examples using the adtran MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB' -M '/opt/observium/mibs/adtran:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB::adGenAOSOverTempProtectionMib'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB' -M '/opt/observium/mibs/adtran:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB::adGenAOSOverTempProtectionMib'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (6)
.1.3.6.1.4.1.664.5.53.1.10
.1.3.6.1.4.1.664.5.53.1.10.0
.1.3.6.1.4.1.664.5.53.99.19
.1.3.6.1.4.1.664.5.53.99.19.1
.1.3.6.1.4.1.664.5.53.99.19.2
.1.3.6.1.4.1.664.6.10000.53.1.10
Dependencies (5) 4 direct · 1 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. SNMPv2-CONFrfc
  3. SNMPv2-TCrfc
  4. ADTRAN-MIBadtran
  5. ADTRAN-AOSadtran
  6. ADTRAN-AOS-OVER-TEMP-PROTECTION-MIBadtranselected
Conformance Groups (1)
Traps which may be used to enhance event driven
management of the chassis's over-temperature protection subsystem.
.1.3.6.1.4.1.664.5.53.99.19.1.1
Compliance Statements (1)

OID .1.3.6.1.4.1.664.5.53.99.19.2.1
The compliance statement for SNMP entities which implement
version 2 of the adGenAosOverTempProtection MIB. When the implementation of this MIB
supports adGenAOSOverTempProtectionNotificationGroup, then such an implementation can claim
full compliance.
Required groups
optional adGenAOSOverTempProtectionNotificationGroup This optional group defines the asynchronous
notifications generated by over-temperature protection events.
Notifications / Traps (4)
NameOIDDescription
.1.3.6.1.4.1.664.5.53.1.10.0.1
An over-temperature warning trap signifies that the warning temperature threshold has been exceeded.
.1.3.6.1.4.1.664.5.53.1.10.0.2
An over-temperature shutdown trap signifies that the shutdown temperature threshold has been exceeded, and the unit will restart into low-power mode.
.1.3.6.1.4.1.664.5.53.1.10.0.3
An over-temperature warning resume trap signifies that the warning temperature threshold has been resumed back to normal.
.1.3.6.1.4.1.664.5.53.1.10.0.4
An over-temperature shutdown resume trap signifies that the shutdown temperature threshold has been resumed, and the unit has come back to normal mode from low-power mode.